Because of an increase in power supply failures of electric energy receivers connected to battery with supply bus via cutout IP-50 on Mi-8MTV-1 helicopters, in accordance with the bulletin No. T3423-БУ-Г and No. T3241-БУ-Г, backup supply line for electric energy receivers is introduced and its electric diagram is modified.

You can only view the directory.
For information concerning to the cost of retrofit and forming retrofit request log in or sign up.

In the process of operation of Mi-8MTV-1 helicopters, there was a number of incidents related to disconnection of DC consumers due to activation of cutouts IP-150 in power circuits feeding battery buses. In such case, flight and navigation equipment and avionics, assemblies of fuel, hydraulic, fire-prevention system become de-energized, that requires forced landing. In connection with this, it was decided to modify the power supply system and introduce backup supply line for electric energy receivers.

As a result of these works, the bulletin No. Т3241-БУ-Г “Introduction of backup supply line for electric energy receivers on Mi-8MTV-1 helicopters”was issued.

However, after implementation of this modification, the cases of false activation of warning panel “LINE ON BAT” took place due to failure of diode item 106/3.

To address this problem, additional modification was developed, which was executed in accordance with No. Т3423-БУ-Г «Modification of electric circuit of supply line for electric energy receivers by circuit of cutout IP-150 item 93/3», to be realized together or after fulfillment of the bulletin No. Т3241-БУ-Г.

 

For installation of backup supply line for power receivers and modification of electric circuit of supply line for electric energy receivers on Mi-8MTV-1 helicopters, according to this service bulletin, it’s required to perform electric installation works as follows:

 

  • modification of distribution box of left instrument panel,
  • installation of display board TS-5M-2,
  • installation of resistor С5-36В-25 W-390 Ohm+0,5%,
  • installation of relay ТКЕ21ПОДГ,
  • installation of cutout IP-150,
  • laying and crimping newly introduced bundles Л14, Л8,
  • installation of diode 2Д220А1 with soldered wire.

 

After completion of the above works, it’s necessary to check serviceability of the system.

 

 